The unsupported length between end restraints, as per the code IS-456, should not exceed ............. times the least lateral dimension of a column.




6) The unsupported length between end restraints, as per the code IS-456, should not exceed ............. times the least lateral dimension of a column.


ans - 60 times



Concept

According to IS 456:2000, the unsupported length between end restraints of a column should not exceed 60 times the least lateral dimension. 

Elaboration:

Clause 25.3.1 of IS 456:2000 specifies that the unsupported length between end restraints of a column should not exceed 60 times its least lateral dimension. 

The unsupported length is the clear distance between members that can provide lateral support to the column. 

For a pin-ended column, it is the distance between the hinges. 